MT9085 Серия оптических рефлектометров ACCESS Master

The ACCESS Master MT9085 series is a compact handheld all-in-one tester for performing optical pulse tests, optical loss/power measurements, and optical fiber end-face inspections. It has a wide variety of applications, ranging from installation and maintenance (I&M) of trunk fibers (Core, Metro, Mobile Fronthaul, Mobile Backhaul) to troubleshooting Access networks, such as breaks in drop cables.

Детальное изображение товара MT9085 Серия оптических рефлектометров ACCESS Master

The ACCESS Master MT9085 series is a compact handheld all-in-one tester for performing optical pulse tests, optical loss/power measurements, and optical fiber end-face inspections. It has a wide variety of applications, ranging from installation and maintenance (I&M) of trunk fibers (Core, Metro, Mobile Fronthaul, Mobile Backhaul) to troubleshooting Access networks, such as breaks in drop cables.

As well as keeping the intuitive operability of previous models using hard keys and rotary knob, the MT9085 has been upgraded with a wide, 8-inch, color, LCD touchscreen. The Fiber Visualizer function has also been taken to the next stage with at-a-glance confirmation of the optical fiber transmission path.

Optical Pulse Test (OTDR)

The optical pulse test measures the optical fiber transmission loss and fiber length as well as detects events, such as breaks in the fiber continuity. Both single mode and multimode fibers are supported, and the product line includes support for various wavelengths matching the measurement environment. The easy-to-use Fiber Visualizer function uses two types of realtime sweep (high-speed, high S/N) to check the status of fiber connections and bends while monitoring the waveform; events on the fiber are detected with high accuracy (46 dB dynamic range max., 0.8 m dead zone) and loss is measured. The excellent waveform quality supports short to long distance optical measurements, including PON and realtime measurement.


Optical Power/Loss Measurement

With a built-in light source and power and loss measurement functions, the all-in-one MT9085 series is ideal for confirming the status of optical fiber installations and fault conditions.


Optical Fiber End-Face Inspection
Optical fiber end-face inspection uses an external fiberscope option (sold separately) to display the condition of the optical connector ferrule end face on the screen of the MT9085 main unit. Optical fiber end-face inspection is important because not only do dirt and scratches on the ferrule face have a major impact on optical fiber circuit transmission quality, but they also prevent accurate optical pulse tests and measurement of optical loss and power.  

8-inch LCD with easy visibility even in direct sunlight
Better work efficiency with synergy of LCD touchscreen, rotary knob, and dedicated hard keys
Familiar functions and operations from previous ACCESS Master series 
  • Easy-to-Use Fiber Visualizer function for simple fiber path analysis
  • Fast fiber bend location using high-speed, high S/N real-time sweep modes
  • High-accuracy event detection and loss measurement (46-dB dynamic range max., 0.8 m event dead zone)
  • Identification of each splitter event and up to 1 × 128 branches
  • Optical loss test and optical power measurement with built-in light source, optical power meter, and visible light source options
  • Optical fiber end-face inspection using external fiberscope option
Сертификат об утверждении типа СИ Да
Дисплей 8"
Размер 284 x 200 x 77 мм
Масса 2,6
Интерфейс USB-данных (хост) A
Время зарядки батареи (ч) 5
Электропитание от сети переменного тока (В 100-240
Электропитание через адаптер/зарядное устройство (Гц) 50-60
Время непрерывной работы питания от батарей (ч) 12
Динамический диапазон 29-46 дБ
Длина волны 1310/1490/1550/1625/1650/850/1300
Название Краткое описание
MT9085C Оптический рефлектометр с большим динамическим диапазоном
MT9085B Оптический рефлектометр со средним динамическим диапазоном
MT9085A Оптический рефлектометр с малым динамическим диапазоном
MT9085C-053 ОМВ 1310/1550 нм (46/46 дБ)
MT9085C-057 ОМВ 1310/1550/1625 нм (46/46/44 дБ)
MT9085B-053 ОМВ 1310/1550 нм (42/41 дБ)
MT9085B-055 ОМВ 1310/1550/1650 нм (41/41/35 дБ)
MT9085B-056 ОМВ 1310/1490/1550 нм (42/41/41 дБ)
MT9085B-057 ОМВ 1310/1550/1625 нм (40/39/38 дБ)
MT9085B-058 ОМВ 1310/1490/1550/1625 нм (42/41/41/40 дБ)
MT9085B-063 ОМВ 1310/1550 нм (42/41 дБ) & ММВ 850/1300 нм (29/28 дБ)
MT9085A-053 ОМВ 1310/1550 нм (39/37,5 дБ)
MT9085A-057 ОМВ 1310/1550/1625 нм (37/35,5/32,5 дБ)
MT9085A-063 ОМВ 1310/1550 нм (39/37,5 дБ) & ММВ 850/1300 нм (29/28 дБ)
MT9085x-002 Визуальный дефектоскоп
MT9085x-004 Измеритель оптической мощности в ОМВ
MT9085x-005 Измеритель высокой оптической мощности в ОМВ
MT9085x-007 Измеритель оптической мощности в ОМВ и ММВ
MT9085x-010 Защита (боковые бамперы, крышка экрана, ремень)
MT9085x-025 Коннектор FC-APC
MT9085x-026 Коннектор SC-APC
MT9085x-037 Коннектор FC
MT9085x-038 Коннектор ST
MT9085x-039 Коннектор DIN 47256
MT9085x-040 Коннектор SC